Networking Transmission Media Tips

Transmission media – The pathway that enables computers to send and receive signals to one another

Physical and Wireless media can connect computers in a network.

Physical Media

Types of Cable Signals

Straight-through cable – The eight wires inside of each RJ45 are in the exact same order (use to connect heterogeneous devices)
(Host to Router, Host to Switch and Switch to Router)

Cross-over cable – The wires 1 & 3, 2 & 6, are reversed (use to connect homogenous devices)
(Host to Host, Switch to Switch and Router to Router)

Rollover or Console cable
– It is a special cable use for console access to a switch or router.

Types of Physical Cable Media

utp
Twisted Pair  (Solid vs. Stranded)
Twisted Pair Cable uses one or more pairs of twisted copper wires to transmit signals

2 types of twisted pair cables

UTP – Unshielded Twisted Pair (Most common)
STP – Shielded Twisted Pair (Protection against EMI)

Cable, Transfer Speed and Bandwidth                                      
CAT3      
10Mbps                                               
16MHz

CAT4      
4-16Mbps (Token Ring)                    
20MHz

CAT5      
10/100Mbps                                      
100-350MHz

CAT5e    
10/100/1,000Mbps                             
100-350MHz

CAT6      
10/100/1000/10,000Mbps                      
100-500MHz

CAT6a    
10/100/1000/10,000Mbps                      
500-1000MHz

CAT 7     
10/100/1000/10,000Mbps                      
700-1000MHz


CAT cables usually connect to an RJ45 connector

RJ45 

Straight Thru-Cable (Heterogeneous Environment)



Cross Over Cable (Homogenous Environment)




1
2
3
4
5
6
7
8
Transmit+
Transmit-
Receive+
Not used
Not used
Receive-
Not used
Not used
Coaxial
Coaxial cable, commonly called coax, has two conductors that share the same axis.

coaxial
Coaxial
Thinnet or 10Base2 cost is cheap RG58 wire with 50 Ohms Terminator
Must use a T connector with BNC and last computer on both ends must be terminated
No more than 30 nodes per segment
Nodes must be space 0.5 meters apart

Thicknet or 10Base5 moderate costs RG8 rated at 50 Ohms connects to an AUI or DIX NIC thru a vampire tap
Nodes must be 2.5 meter intervals
No More than 100 Nodes per segment

Use
Type of Coaxial Cable
Termination
Connector
10Base2 (Thinnet)
RG58
50ohmn
BNC
10Base5 (Thicknet)
RG8
50ohmn
AUI/DIX
Cable TV
RG59 (analog)
RG6 (digital)
75ohmn
F
coaxial
Coaxial Cable


Fiber-Optic
Fiber-Optic cable transmits light signals rather than electrical signals.

Most expensive physical media usually use as backbone or a high speed connection
fiber
Multi mode Fiber (MMF) - use LED light emitting diode found on most high speed networks use for shorter distances

Single mode Fiber (SMF) - use Laser to transmit signal mostly for longer distances

Fiber Optic Connectors

ST

SC

MTRJ

LC

ST – Straight Tip Connector
SC – Square Connector

SFF (Small Form Factor) Fiber Optic connectors

MTRJ- Mechanical Transfer Registered Jack
LC – Local or Lucent Connector

Advantage:
Speed, Distance, Security and Immune to EMI

Disadvantage:
Cost, Difficulty of installation and Flexibility
Transmission Degradation of Physical Media

Attenuation – Loss of signal as it goes to a transmission media.
Crosstalk – a form of EMI caused by wires to interfere next to each other
Dispersion – applies to fiber optic cables.
Fire Ratings - Plenum (Non Flammable fire rating for cables) vs. PVC Poly Vinyl Chloride

Wireless Media



Radio Waves – use radio signals to communicate, the three types of radio waves are low power, high power and spread spectrum broadcasts.
microwave

Microwave Transmission - most popular long distance transmissions found in networks. It uses line-of-sight communication.
Microwave systems consist of 2 radio transceivers: one to transmit and one to receive.  These antennas are usually installed on towers to give them more distance and speeds.


Infrared- uses infrared light to transmit signals. Infrared signals cannot penetrate walls or other thick objects


Satellite - Uses Satellite Technology to transmit signals. (Direct TV)

Install components of wiring distribution
Distribution Frame
MDF stands for Main Distribution Frame and IDF stands for Independent Distribution Frame.
The MDF is the main computer room for connecting servers, switch, routers, DSL's, etc. to reside.

The IDF is a remote room or closet connected to the MDF. In the IDF you can expect to find hubs and patch panels.
cabling

Cross connects - A device that allows conductors or channels to be interconnected, either physically or electronically, on a semi-permanent basis. A cross-connect can be in the form of a main distribution frame (MDF), intermediate distribution frame (IDF), or terminal block where wire pairs from cables are mechanically terminated on a punch-down block, with short wire jumpers interconnecting the cable pairs on each side of the block.
A cross-connect is a location within a cabling systems that facilitates the termination of cable elements plus the reconnection of those elements with jumpers, termination blocks, and/or cables to a patch panel and so on. It’s where all the wires come together
Cables that run from communication closets to wall outlets are known as horizontal cables, because there are generally used on the same floor of building.

Backbone cables that connect equipment rooms, telecommunication rooms and other physical termination points are referred to as vertical cables, because they are often from floor to floor in a building.

A patch panel or patch bay is a panel, typically rack-mounted, that houses cable connections. One typically shorter patch cable will plug into the front side, whereas the back holds the connection of a much longer and more permanent cable. The assembly of hardware is arranged so that a number of circuits, usually of the same or similar type, appear on jacks for monitoring, interconnecting, and testing circuits in a convenient, flexible manner.


The 25-pair color code is a color code used to identify individual conductors in a kind of electrical telecommunication wiring for indoor use, known as twisted pair cables. The colors are applied to the insulation that covers each conductor.

The 100-pair color code is another type of wiring use for telecommunications and networking.
A 66 block (also M-Block) is a type of punch down block used to connect sets of wires in a telephone system.
A 110 block is a type of punch block used to connect sets of wires in a structured cabling system.
A demarc (an abbreviation for demarcation point) marks the point where communications facilities owned by one organization interface with that of another organization.
A demarc extension refers to the process of installing additional wiring from the main connection
In telecommunications, a network interface device (NID) is a device that serves as the demarcation point between the carrier's local loop and the customer's premises wiring.
Generically, NIDs may also be called a network interface unit (NIU) or telephone network box. A smart jack is a type of NID which has capabilities beyond simple electrical connection (such as diagnostics). An optical network terminal (ONT) is a type of NID used with fiber-to-the-premises applications.